Kryp­ton­ian Vi­sion

Su­per­man, a Kryp­ton­ian, uses his X‑Ray vi­sion. Source

by Jen­nifer Gutier­rez

X‑ray vi­sion, once the ex­clu­sive do­main of Su­per­man and his su­per hero kin, is now a tool in the bi­o­log­i­cal re­searchers kit. Granted, not every re­searcher has ac­cess to this su­per­power; the re­quired syn­chro­tron light sources are found only at large re­search fa­cil­i­ties that hap­pen to have a par­ti­cle ac­cel­er­a­tor at hand. Still, it is surely worth the bother. Com­pared to elec­tron mi­croscopy, sam­ples can be im­aged in a more nat­ural state with­out be­ing ei­ther em­bed­ded or frozen, and they can be larger. Com­pared to light mi­croscopy, the smaller wave­length of x‑ray ra­di­a­tion has the po­ten­tial to pro­vide higher res­o­lu­tion. Res­o­lu­tion had been com­pli­cated by the dif­fi­culty in mak­ing ef­fi­cient lenses, but new tech­niques in both lens de­sign and man­u­fac­ture are be­ing de­vel­oped. The lens prob­lem can be cir­cum­vented us­ing lens-less mi­croscopy, as em­ployed in a re­cent pa­per by Klause Gieweke­meyer et al.

The Swiss Light Source at the Paul Scher­rer In­sti­tut, a third-gen­er­a­tion syn­chro­tron light source. Source

The data they re­ported was gen­er­ated at the Swiss Light Source (SLS) in Vil­le­gen, Switzer­land, an in­ter­na­tional cen­ter for x‑ray mi­croscopy. This fa­cil­ity uti­lizes a third gen­er­a­tion syn­chro­tron light source (what­ever that is. I warn you, this is com­pli­cated. This and the next para­graphs are for those who care to know how it works). Here the light is gen­er­ated by first ac­cel­er­at­ing elec­trons us­ing a large se­ries of mag­nets in a lin­ear ac­cel­er­a­tor, next in­creas­ing the ac­cel­er­a­tion fur­ther with more 'booster' mag­nets, and then stor­ing the ac­cel­er­ated elec­trons in a se­ries of 'un­du­la­tors.' These un­du­la­tors were de­vel­oped in the 1970's at Berke­ley and move the elec­trons around a cir­cu­lar ar­ray of pe­ri­od­i­cally-spaced mag­nets, caus­ing them to slalom as they cir­cle. This step al­lows the re­searchers to se­lect the wave­length of elec­tron ra­di­a­tion to be used in the il­lu­mi­na­tion beam (syn­chro­tron light), rang­ing from ul­tra­vi­o­let to hard x‑rays, de­pend­ing on their imag­ing goals.

In­side the SLS fa­cil­ity. Source

Beam co­her­ence is very im­por­tant when imag­ing bi­o­log­i­cal spec­i­mens, and the SLS setup specif­i­cally pro­vides a bright, co­her­ent, small-di­am­e­ter x‑ray beam. The lens-less setup used here does not cre­ate a high res­o­lu­tion im­age di­rectly, as elec­tron and light mi­cro­scopes do, but rather gen­er­ates a dif­frac­tion pat­tern from which an im­age can be com­pu­ta­tion­ally back-pro­jected. Co­her­ent X‑Ray Dif­frac­tion Imag­ing (CXDI) in­volves mov­ing a sam­ple rel­a­tive to a small il­lu­mi­nat­ing beam and col­lect­ing dif­frac­tion pat­terns from mul­ti­ple, over­lap­ping spots of the sam­ple, even­tu­ally col­lect­ing data from the en­tire spec­i­men. A com­puter then sews to­gether a unique im­age based on the align­ment of all the col­lected pat­terns. For the work re­ported here, CXDI was com­bined with a sec­ond tech­nique, pty­chog­ra­phy (from the Greek πτνξ mean­ing fold), that uses com­pu­ta­tional power and it­er­a­tive al­go­rithms to solve the 'phase prob­lem' gen­er­ally as­so­ci­ated with x‑ray meth­ods. The au­thors used this com­bined ap­proach, termed Pty­cho­graph­i­cal Co­her­ent Dif­frac­tive Imag­ing (PCDI), to im­age freeze-dried Deinococ­cus ra­dio­du­rans cells — the first ex­am­ple of ap­ply­ing PCDI to a bi­o­log­i­cal sam­ple. They have demon­strated that it does, in fact, work. (For a re­view of PCDI, click here.)

Trans­mis­sion elec­tron mi­cro­gragh (TEM) of Deinococ­cus ra­dio­du­rans. Source

D. ra­dio­du­rans is used in biore­me­di­a­tion due to its re­mark­able abil­ity to with­stand high amounts of ra­di­a­tion — 5000 Gy causes no loss in vi­a­bil­ity. How­ever, its spe­cial abil­i­ties don't end there; D. ra­dio­du­rans is also re­sis­tant to acid, cold, vac­uum, and de­hy­dra­tion! (For a re­view of the ca­pa­bil­i­ties of D. ra­dio­du­rans, click here.) It is not clear ex­actly how it ac­com­plishes this poly­ex­tremophile feat, but we have some clues. First, while D. ra­dio­du­rans ap­pears to ex­pe­ri­ence the same amount of DNA dam­age as E. coli when ex­posed to ra­di­a­tion, it has a higher DNA recombination/repair rate that, it has been sug­gested, may be fa­cil­i­tated by its un­usual DNA struc­ture (4 copies of the genome, per­haps or­ga­nized into ring-like sec­ondary struc­tures). These speedy bac­te­ria can re­pair their en­tire genome in about 3 hours af­ter ex­pe­ri­enc­ing a ra­di­a­tion dose of 6,800 Gy! Sec­ond, its high in­tra­cel­lu­lar manganese/iron ra­tio pro­tects the pro­teins in the cell from dam­age by re­ac­tive oxy­gen species. This ra­tio is known to be im­por­tant in bac­te­ria for re­sis­tance to ion­iz­ing ra­di­a­tion and des­ic­ca­tion, both of which cause DNA breaks. Its ac­tion is thought to mimic the func­tion of cata­lase and su­per­ox­ide dis­mu­tase (of which D. ra­dio­du­rans has three each), thus al­low­ing the cel­lu­lar pro­teins to func­tion ef­fi­ciently im­me­di­ately af­ter DNA dam­age has oc­curred. This pa­per ap­plies the new tech­nique of PCDI to im­age the nu­cleoids of D. ra­dio­du­rans, thus ex­pand­ing ear­lier struc­tural stud­ies. Four DNA quad­rants are dis­cern­able in­side many cells, while some cells show only two.

Re­con­structed phase map of a PCDI scan on a tetramer of D. ra­dio­du­rans cells. Source

While the im­ages pre­sented here are ac­cu­rate and in­ter­est­ing, some ques­tions re­gard­ing the use­ful­ness of this tech­nique per­sist. No­tably, the res­o­lu­tion of the im­ages shown in the pa­per doesn't ap­pear to be able to shed light on the or­ga­ni­za­tion within the nu­cleoid it­self, merely on the po­si­tion of nu­cleoids rel­a­tive to each other in­side the cell, and pos­si­bly on the level of DNA con­den­sa­tion. The au­thors sug­gest that com­bin­ing to­mo­graphic meth­ods with PCDI will solve this prob­lem, but as with all types of to­mog­ra­phy, so many im­ages need to be col­lected that the ra­di­a­tion caused by the col­li­sion of beam elec­trons with the sam­ple be­comes lim­it­ing. It is un­clear to me that res­o­lu­tion will be high enough when doses are made low enough for PCDI to­mog­ra­phy. Also, to the best of my knowl­edge non-dis­rup­tive la­bel­ing meth­ods (those not re­quir­ing fix­a­tion) do not yet ex­ist for x‑ray mi­croscopy, fur­ther com­pli­cat­ing in­ter­pre­ta­tion of the den­sity pat­terns present in the im­ages.

Nev­er­the­less, this work rep­re­sents a step for­ward in x‑ray mi­croscopy and high­lights the po­ten­tial of this lens-less tech­nique to gen­er­ate a den­sity map re­veal­ing the in­ter­nal struc­ture of un­stained bi­o­log­i­cal sam­ples, such as an en­tire D. ra­dio­du­rans cell. It could be par­tic­u­larly use­ful for ex­am­in­ing the role of DNA con­den­sa­tion in ra­dio-re­sis­tance (for in­stance by com­par­ing DNA den­sity maps of wild-type cells to those of non-re­sis­tant mu­tants) or for ex­plor­ing the DNA or­ga­ni­za­tion of other bac­te­ria — a long-stand­ing ques­tion ill-ad­dressed by light mi­croscopy (in­ad­e­quate res­o­lu­tion) and cry­o­elec­tron mi­croscopy (in­ad­e­quate con­trast).

 

Ref­er­ence

Gieweke­meyer K, Thibault P, Kalbfleisch S, Beer­link A, Kewish CM, Dierolf M, Pfeif­fer F, Salditt T. (2010). Quan­ti­ta­tive bi­o­log­i­cal imag­ing by pty­cho­graphic x‑ray dif­frac­tion mi­croscopy. Proc. Natl. Acad. Sci. USA, 107 (2), 529−534 PMID 20018650

 

Jennifer Gutierrez

Jen­nifer is a mi­cro­bi­ol­ogy grad­u­ate stu­dent in the Joint Doc­toral Pro­gram of San Diego State Uni­ver­sity and Uni­ver­sity of Cal­i­for­nia at San Diego. She works in Kit Pogliano's lab.

 

Other Posts

  • Time's Up

    by Merry Youle — Holins are the small­est known bi­o­log­i­cal timers. Timers, not clocks. Timers tick along, then go off af­ter the spec­i­fied in­ter­val. These small, phage-en­coded pro­teins time the length of lytic in­fec­tions of some phages. When they go off, the game is over and...

  • Sex And Evo­lu­tion, Vib­rio Style

    by J. Jef­frey Mor­ris — My wife is an avid ge­neal­o­gist and I'm an evo­lu­tion­ary bi­ol­o­gist, so fam­ily trees come up for dis­cus­sion from time to time around the din­ner ta­ble. Laura al­ways imag­ines fam­ily trees as ex­tend­ing up­ward from a cur­rently liv­ing per­son to in­clude all their an­ces­tors, whereas I al­ways think of them as point­ing down­ward from a com­mon an­ces­tor to all their de­scen­dants. Ob­vi­ously, I think my way is the right way...

  • Chro­mo­some Or­ga­ni­za­tion the Pseudo­monas Way (2|2)

    by Christoph — Over the last twenty years, mol­e­c­u­lar bi­ol­o­gists de­vel­oped and re­fined a down­right cute method to study bac­te­r­ial chro­mo­some or­ga­ni­za­tion in live cells. Briefly, a clus­ter of bind­ing sites for a DNA-bind­ing pro­tein is in­tro­duced at a cho­sen lo­cus of a bac­te­r­ial chro­mo­some via ge­netic en­gi­neer­ing (=cloning). A plas­mid is in­tro­duced with the gene...

  • How Do You Know There Is a Nu­cleoid?

    Pic­tures Con­sid­ered #3 by Elio — What is more com­mon­place than say­ing that prokary­otic cells pos­sess a nu­cleoid? It is im­plicit in the term prokary­ote it­self. Still, it was not shown de­fin­i­tively un­til the 1940s that bac­te­ria and ar­chaea have such dif­fer­en­ti­ated struc­tures made up of con­densed DNA. It was the care­ful work of "bac­te­r­ial…

  • Tal­mu­dic Ques­tion #114

    The year is 2124. Thanks to new im­prove­ments in tele­por­ta­tion, the In­ter­galac­tic Re­search In­sti­tute has gath­ered 1000 bi­o­log­i­cal sam­ples from each of 1000 hab­it­able plan­ets in 1000 galax­ies. The sam­ples were an­a­lyzed with new model In­stant An­a­lyz­ers ca­pa­ble of de­ter­min­ing…

  • How E. coli Rose to Promi­nence – An Ad­den­dum

    by Roberto — In an era of mi­cro­bi­ol­ogy largely dom­i­nated by re­search sur­round­ing pre­vi­ously unimag­in­able ex­tent of mi­cro­bial di­ver­sity, here at STC we still have a strong af­fec­tion for the ad­vances made in­ves­ti­gat­ing model bac­te­ria; prime amongst these is E. coli. Thus, it is no sur­prise that we are fas­ci­nated by the his­tory of E. coli re­search.

4 Comments
Oldest
Newest Most Voted
16 years ago

Jen­nifer, what a won­der­ful job! I'm quite in­spired to do more sci­ence writ­ing, my­self. Thanks for such an in­ter­est­ing view of mi­cro­bi­ol­ogy (and for in­clud­ing Kal-El).

Nathan Myers
16 years ago

An in­ter­est­ing quan­ti­ta­tive spec­u­la­tion on the ori­gin of re­sis­tance to ra­di­a­tion dam­age:
http://www.geosociety.org/gsatoday/archive/19/10/article/i1052-5173–19-10–4.htm
Merry adds a thank you for bring­ing this to our at­ten­tion.

sachin kumar sharma
16 years ago

magic of sci­ence

16 years ago

I think you have done great job by writ­ing in­ter­est­ing things about sci­ence and mi­cro­bi­ol­ogy. This would def­i­nitely in­spire oth­ers to do this kind of re­search.